As this error implies that your program logic contains a mistake, you might want to terminate the run and recode your program. 009 No room in directory (Recoverable) The system cannot The process was not created properly, or has ended prematurely. Or maybe looping on reading the char until you get a valid input for that, and then reading the real. As this error implies that your program logic contains a mistake, you might like to close any files which are open, execute a STOP RUN statement and recode. 152 REWRITE on Check This Out

You might need to use one of the Compiler directives, BADSIGNS, HOST-NUMCOMPARE, SIGNCOMPARE or SPZERO, to resolve invalid data in numeric fields. This could be because the file was created either under a different operating system or under a previous version of your current system. The second optional line is output only if the file rts.err is available in an open library. 32-bit: The 32-bit COBOL sytems display run-time system messages in one of the following Repeat the file operation. 028 No space on device (Fatal) You have tried a file operation such as WRITE for which insufficient space is available on your disk. http://www.freepascal.org/docs-html/user/userap4.html

Dos Runtime Error 200

coblongjmp() must be called only from the same or from a lower level in the CALL/PERFORM hierarchy as the corresponding cobsetjmp() or cobsavenv(). Check to see that you used a valid call number in the unsuccessful subroutine call. Check that Adis or the External File Handler is is configured correctly. Ensure that you are in the correct directory or that a path to the file concerned exists.

This could be because it was created under a previous version of the system or it could have been created under a completely different operating system. You should rerun your program using the backup copy of that file. You should then be able to continue to run your program. 066 Attempt to add duplicate record key to indexed file (Fatal) You have tried to add a duplicate key for Types Of Errors In Pascal Programming Contact Technical Support who will help you find the cause of your error and how it can be rectified. 102 Sequential file with non-integral number of records (Fatal) You have either

You might have tried to load intermediate code that either has not been successfully produced, or has been corrupted in some way. Resolution: Check the syntax of the entries in the configuration file. Rename your program. 004 Illegal file name (Recoverable) A file-name contains an illegal character. Alternatively, if you have COBFSTAT environment variable set to HOSTSTAT, this could be mainframe file status code "97".

You should edit your source code to correct all the severe faults, resubmit it to your COBOL system, then run the intermediate code that is produced. Pascal File Handling Alternatively, the record key which you have specified is too large for the system to deal with successfully, or the pointer to the record has been corrupted in some way so Your operating system might enable you to increase the maximum number of processes allowed. Abstract methods should be overridden, and the overriding method should be called. 212 Stream registration error This occurs when an invalid type is registered in the objects unit. 213 Collection index

Runtime Error 106 Pascal

Resolution: Recode your program. 146 No current record defined for sequential read (Recoverable) The file position indicator in your file is undefined owing to a failed read/START or INVALID KEY condition. http://www.frameworkpascal.com/helphtml/run_errors.htm Always keep your programs updated with the latest release of patches and bug fixes; A runtime can also seen to be caused by plug-ins, add-ons or some added software installed on Dos Runtime Error 200 You are probably trying to execute a corrupted file or one which has not been submitted to your COBOL system successfully. Pascal Exit Code 201 Typically happens when you try to read past the end of a file. 101 Disk write error Reported when the disk is full, and you're trying to write to it. 102

Once you have taken these steps, run your program again. 180 End-of-file marker error (Fatal) A file-marker used to indicate that the end-of-file has been reached is missing from one of his comment is here You should obtain more memory in which to run your program. Contact Technical Support who will help you find the cause of your error and how it can be rectified. 082 CALL convention not supported (Fatal) The CALL convention you have specified Resolution: Rerun your application with a valid command line. Pascal Exit Code 106

You are probably trying to execute a corrupt file or one which has not been produced. This error might be caused by one of several reasons: Trying to open for writing a file which is read-only, or which is actually a directory. It's all supposed to be pretty simple, everything compiles ok, no errors are brought up, it reads the text files and works the pay correctly but then when it comes to this contact form If it is part of a .dll or .lbr file, ensure that the containing file has been loaded with a CALL statement before sending messages to any of the classes.

Continue until you notice that the run-time error has disappeared after ending a particular program; Update the identified program which was causing the conflict from the software developer’s homepage and see Runtime Error 216 Wait fir it: "Invalid numeric format". Resolution: You should resubmit your code to your COBOL system, or use a debugger to place the end-of-file marker at the end of the file.

You can then rerun your program. 181 Invalid parameter error (Fatal) A parameter which you have used is not one which is recognized by your system.

Alternatively, specify a different drive or directory for your file operations. 010 File name not supplied (Recoverable) You have tried to open a file that you have declared as an external Resubmit your source code to your COBOL system. Ensure that all the system programs are available on the logged-in drive and copy those which are not currently present using your backup system disk. How To Fix Runtime Error See your Programmer's Guide to File Handling for details.

If this does not work, contact Technical Support who will help you to find the specific cause of the error. 121 Symbol is not in TEXT section (Fatal) You have tried You should resubmit your source program to your COBOL system, to try to obtain uncorrupted intermediate code. 162 Arithmetic overflow or underflow (Fatal) You are executing a program that is trying Ensure that the run-time system is on the path you have set up in the COBDIR environment variable. navigate here Resolution: Open the device in the correct mode or close any open files, do STOP RUN and recode your program.

So I think there is an error in your DATA ie: Real. See your Object COBOL User Guide for a list of supported CALL conventions. 086 Remote file system failure (Fatal) 099 Illegal operation in SORT/MERGE module (Fatal) A SORT or MERGE module Resolution: You should resubmit your program using a non-Japanese run-time system, or if you still want your program to perform Japanese operations, you should acquire a Japanese run-time system. 173 Called Contact Technical Support who will help you to discover the cause of the error. 201 I-O error in paging system (Fatal) No room is available in your current directory or on

Recode your program. 146 No current record defined for sequential read (Recoverable) The file position indicator in your file is undefined owing to a failed read/START or INVALID KEY condition. Resolution: You should close some of the indexed files which you are no longer accessing, and you should then be able to open the file you require. Resolution: Once your program has terminated you should copy the relevant file into your logged-in drive or directory. If you are not the owner of the file you cannot carry out that operation successfully unless you copy the file and make the changes to the copy only.

Resolution: Adjust your code so that no invalid data is used. Resolution: Your program has a fault, so you probably should edit your code, then resubmit it to your COBOL system before running it again. 141 File already open - cannot be Refer to your operating system documentation for details of how you can obtain more memory, if this is possible. 106 Dictionary error (Fatal) This could be the result of a read If you cannot recode the DLL, you can set the O RTS switch to force a logical cancel on the DLL.

This can be a software or an operating system restraint, but you must not violate it. If insufficient space is available, you should set the COBDIR environment variable to search the directory or drive on which the file is present when your program calls it. You would also receive this error if you tried to load a disk with a name that clashed with a disk that was already loaded. Resolution: Contact Technical Support who will help you to discover the cause of your error and how it can be rectified.

Locate the missing file and ensure it is located on the default search path for your operating system. 175 Attempt to run intermediate code program which had severe errors in it